• NDX<sup>&reg;</sup> NDX® Heat source ground
    NDX®

    Heat source ground

    The 'D' in 'NDX' stands for 'direct', and is the most ground-breaking method of using the heat of the ground efficiently. Directly and without any diversions for maximum effect.

    Highlights:

    • Highest efficiency
    • Plug & Heat system
    • Quiet and efficient operation thanks to scroll technology
    • 10 year Premium Warranty
    • Supports WEBDIALOG®
  • NDB<sup>&reg;</sup> NDB® Heat source deep drilling
    NDB<sup>&reg;</sup>
    NDB®

    The deep drilling technology offers the optimum solution of an excellent heat source especially in the event of small space availability.


    Highlights:

    • Highest effectiveness
    • May be installed inside or outside - no need for a technical room
    • Plug & Heat - ready-to-work, delivered from the factory after testing
    • Heating and cooling possible
    • 10 year Premium Warranty
    • Supports WEBDIALOG®
    NDB<sup>&reg;</sup> PICO
    NDB® PICO

    The deep drilling technology offers the optimum solution of an excellent heat source especially in the event of small space availability.


    Highlights:

    • Highest effectiveness
    • Very small (lowest space requirement)
    • Plug & Heat - ready-to-work, delivered from the factory after testing
    • Heating and cooling possible
    • 10 year Premium Warranty
    • Supports WEBDIALOG®
  • NDW<sup>&reg;</sup> NDW® Heat source ground water
    NDW®

    Heat source ground water

    Thanks to the NEURA NDW ground water thermal heat pump you can use an energy source that especially useful in small gardens in order to achieve highest efficiency - 365 days of the year

     

    Highlights

    • Highest working efficiency
    • Plug & Heat - ready-to-work, tried and proven delivery from the factory
    • Cooling option
    • May be installed inside or outside - no need for a technical room
    • 10 year Premium Warranty
    • Supports WEBDIALOG®
  • NDA<sup>&reg;</sup> PREMIUM NDA® Heat source air
    NDA<sup>&reg;</sup> PREMIUM
    NDA® PREMIUM
    • Top efficiency - low consumption of electricity
    • Exceedingly quiet operation
    • Outside installation - no need for a technical room
    NDA<sup>&reg;</sup> NANO
    NDA® NANO
    • Top efficiency - low consumption of electricity
    • Outside installation - no need for a technical room
    • 10 year Premium Warranty
NDX
Heating-
cost

Heating-
cost
calculator

Calculate your personal potential savings on heating costs!
Living space/m²:
1 2 3
Proceed to step 2 further input options
NDX® Wärmepumpe

NDX®

Heat source ground

 

Thanks to the NDX technology® by NEURA it is possible to transfer energy from the ground directly to the heat pump. Thanks to your NEURA heat pump you can smile despite increasing prices of fuel oil, gas and solid fuels.

And that is because you are heating your house economically and in an environmentally friendly way by using free energy from the environment.

Home-made energy, free of charge

Using your plot of land you will become your own energy provider using the NEURA NDX® ground source heat pump. Thanks to the sun, the rain and geothermal energy your garden will always be 'charged' just like an energy storage unit. Even at very low outside temperatures you will enjoy a constantly available heat source.

The perfect combination

Our optimally conducting copper absorbers laid out in the garden are a guarantee of top operational safety. It is in these absorbers, which are connected directly to the NEURA NDX® ground source heat pump, where the working medium circulates. You have no limitations in terms of garden design - everything is possible excluding plants with deep-reaching roots.

Plug&Heat® – Install & heat

The NEURA NDX ground heat pump is filled at the factory with a cooling medium and tested. It only needs to be connected to the heating system at hour side. There is no need for the usual personnel evacuation, filling and soldering work at the site.

Why it makes your life more comfortable:

  • high efficiency, high capacity even during low temperatures
  • requires only a small area for placement (less than in the case of brine-based systems)
  • Plug & Heat: the simplest installation; ready-to-work, tested delivery straight from the factory
  • no limitations on garden design (excluding deep-rooted plants)
  • thanks to Web Dialog you can access your thermal heat pump any time from anywhere in the world

Direktverdampfung - Heat source: ground

1Ground collector
2NDX® ground thermal heat pump
3House connection
4TRS Room adjustment unit
5Heating circuit distribution unit
6Floor heating
7Wall heating
8LW 640 hot water thermal heat pump
1

Ground collector

The cooling medium is pumped directly through the collector piping, absorbing the energy of the ground and thus turning into vapour.
2

NDX® ground thermal heat pump

The cooling medium is compressed and thus 'pumped' up to a higher temperature level. The warmth collected in the cooling medium is transferred to the heating system water in the condenser.
3

House connection

The insulated house connectors are the way between the heat pump and the technical room. The hot heating water flows in the pipes.
4

TRS Room adjustment unit

The room adjustment unit reports the heat requirements to the heat pump
5

Heating circuit distribution unit

The individual heating circuits are arranged in such a way so that each room may reach the temperature required by the operator.
6

Floor heating

The heat taken from the ground is dispersed through the floor to the individual rooms.
7

Wall heating

The warmth taken from the ground may also be easily utilised through wall heating.
8

LW 640 hot water thermal heat pump

Thanks to the LW640 you have at your disposal a small compact thermal heat pump for the purpose of warming your usable water. The heat pump is installed directly on the boiler.

Your clear advantages:

  • World class efficiency
  • No losses generated by second heat exchanger
  • Low space requirement

Reliable high level performance with scroll compressor technology

By using advanced European-manufactured scroll compressors, NEURA ensures the quality of its heat pumps remains consistently high.

 

Maximum efficiency and reliable operation are guaranteed thanks to the number of moving parts within the system being reduced to a minimum.

 

Their optimised operation makes NEURA heat pumps exceptionally quiet.

Quiet and efficient operation

Whether for a new build or modernisation project – NDX® technology is always the right choice. Quiet and efficient operation thanks to scroll technology!

 

 

Why does this make your life easier:

  • Increased operational safety due to low component numbers
  • Stepless electric rotation speed adjustment (PCS technology)
  • Optimum relation between outside temperature and thermal heat pump

Technische Daten

D6EuC - 400V/230V D8EuC - 400V/230V D10EuC - 400V/230V D14EuC - 400V/230V D18EuC - 400V/230V D20EuC - 400V/230V
E4/W35 Heizleistung [kW] 6,60 8,40 10,80 15,90 18,90 21,30
E4/W35 Leistungszahl [COP] 5,00 5,10 5,00 5,00 5,00 5,00
E4/W55 Heizleistung [kW] 5,50 7,40 9,40 13,70 16,90 18,80
E4/W55 Leistungszahl [COP] 2,90 2,90 2,90 3,00 3,00 2,90
Kältemittel R410A Füllmenge [kg] 5,1 5,7 6,5 7,2 7,9 8,9
Erdkollektorfläche [m2] 180 225 270 360 450 540
Maximale Vorlauftemperatur 62° 62° 62° 62° 62° 62°

What does the COP value or the performance coefficient tell us?

COP stands for Coefficient of Performance. A COP informs of the effectiveness of a thermal heat pump. The higher the COP, the more energy may be produced from 1 kW of electric power. The COP is sometimes called the performance coefficient.

 

Example: In the case of a COP of 5 one can get 5 kW of heating power from 1 kW of electric power used.

How much collector area do I need?

All NEURA thermal heat pumps are created exactly according to your individual needs. The required collector area is thus calculated by a NEURA employee according to your requirements. In order to provide you with a ballpark figure: The collector area should be more or less double that of the area to be heated.

 

Do I need a technical room for the thermal heat pump?

Thermal heat pumps working on propane (R 290) have to be installed outside. Heat pumps using the medium R 410 A may be installed either inside or outside. You will receive all the necessary advice from a NEURA employee.

What are the available modes of operation?

Monovalent: The thermal heat pump is planned so that it can cover the entire heating requirements of the house.

 

Bivalent, alternative: The thermal heat pump operates to a specific outside temperature, and afterwards switches off. The required remaining heat is then generated from an additional source (electric heating element, wood-burning boiler, etc.)

 

Bivalent, parallel: The thermal heat pump operates to a specific outside temperature alone, and afterwards switches an additional heat source on, in order to cover the entire requirements of the house or building.

Family S., 5320 Henndorf am Wallersee, Austria

Year of construction 2005
Heated area 180 m²
House type Brick building with full thermal insulation - new construction including warm water generation
Number of persons 4
Heat pump NEURA NDX® ProD7/14Wi
Customer comment

"We wanted to have everything from one supplier - thermal heat pump, ventilation and the home systems. That is why we chose NEURA!"

Family H., 4320 Perg, Austria

Year of construction 2009
Heated area 135 m²
House type New build (lowest-energy house)
Number of persons 4
Heat pump NEURA NDX® Pro D4/8Wi
Customer comment

We have decided for a NEURA geo-thermal heat pump with surface collectors for the following reasons:
- Cost-benefit
- Energy efficiency
- Affordable installation
- Space-saving
- The quick and uncomplicated installation of the surface collectors, approx. 1 day with excavation work
- Economy of space due to outside installation of the pump, operator control module very space-saving
- Very low heating costs: Altogether, meaning heating, water and power € 100. – per month
- No great maintenance work, all clean

Family L., 4813 Altmünster, Austria

Year of construction 2005
Heated area 200 m²
House type Brick building with full thermal insulation - new construction
Number of persons 3
Heat pump NEURA ProD7/14Wi
Customer comment

"Excellent overall conceptt!"

Family E., 4181 Oberneukirchen, Austria

Year of construction 2003
Heated area 320 m²
House type New build
Number of persons
Heat pump NEURA NDX® Pro D9/18Wi
Customer comment

"We have obtained our heat pump in 2003 and have moved into the house in 2005.
Since then we heat a living area of 320m² with 800m² surface collectors. We have bought the system via the EWH company.
We are satisfied customers and can “warmly” recommend the NEURA heat pump!"

Family S., 9581 Ledenitzen, Austria

Year of construction 2010
Heated area
House type New build
Number of persons
Heat pump NEURA NDX® Pro D10 EuP
Customer comment

"I have a heat pump with surface collector as heater in my house, as well as a hot-water heat pump (air) in the basement for production of hot water. The separation was sensible from a cost of operation perspective.
 
The consultation and installation by NEURA has been very proficient and friendly and is advisable any time."

Mr Ch., 2453 Sommerein, Austria

Year of construction 2002
Heated area 230 m²
House type Brick building without full thermal insulation - new construction
Number of persons 2
Heat pump NEURA ProD7/14Wi
Customer comment

"I had taken the picture of the house after I had come back from a long training course. The house was already pleasantly warm thanks to the NEURA ground thermal heat pump!"

Family P., 3304 St. Georgen am Ybbsfeld, Austria

Year of construction 2000
Heated area 140
House type Neubau
Number of persons 1
Heat pump NEURA NDX® Pro D7/14Wi
Customer comment

"I have moved into this house equipped with NEURA heat pumps (geo-thermal and hot-water) in March 2011. One of the reasons for me to decide to move into this house was the heating system by NEURA and I was a little surprised of how favourable and reliable this plant works.
I currently inhabit on my own the ground-floor of my house with 140 m².  The house was built in 1999 - 2000, the 38 cm bricks and the many windows allow a great deal of heat to pass through, the house additionally heats up in the sunshine due to the windows, due to the regulation of the floor sensors I have very little fluctuation in temperature.
The advantages of this system for me are the low effort and the safe and reliable function, as well – even if no one is home for several days."

Family W., 8430 Leibnitz, Austria

Year of construction 2011
Heated area 160 m²
House type New build
Number of persons 2
Heat pump NEURA NDX® Pro D10 EuP
Customer comment

"Our house has been built in 2011 and is located in Southern Styria approx. 270 m above sea level. The particular emphasis has been insulation.
 
We live in the house as a pair and heat a living area of approx. 160 m² on two floors.
The NEURA geo-thermal heater went into operation at Christmas the previous year and was running completely satisfactory, even when we had an outside temperature of minus 18° Celsius. It was pleasantly and consistently warm in the entire house. The heater was running error-free and has never caused uncomfortably strong floor heating.

 

I cannot report any useful experiences about the consumption, because on the one hand we have dried out the floor with the floor heating system before we moved in and the house has actually been built and completed in only seven months."


 

Mr K., 83109 Grosskarolinenfeld, Germany

Year of construction 2002
Heated area 400 m²
House type Brick building with full thermal insulation - new construction
Number of persons 3
Heat pump NEURA ProD15/30W
Customer comment

"The price/performance ratio was very good"

Family S., 4694 Ohlsdorf, Austria

Year of construction 2001
Heated area 176 m²
House type Prefabricated wood frame house - new construction
Number of persons 4
Heat pump NEURA ProD7/14Wi
Customer comment

"We are very satisfied and happy with the low heating costs!"

Family K., 9871 Seeboden, Austria

Year of construction 2010
Heated area 140
House type New build
Number of persons
Heat pump NEURA NDX® Pro D10 EuS
Customer comment

"We are very satisfied with this solution. We have a ground heat pump for a living area of 140 m². Service water is provided by an electric boiler.


Since our house has very good insulation values (23 KW/m²/year), we maintain an average temperature of 22.32°C throughout the year. (Summer cool, winter warm). The heating costs are approx. € 400 p.a.

We have also connected the washing machine and the dishwasher to the hot water. As a result we have 10% less power consumption and faster washing cycles. Total power for household and heat pump 4466 kWh p.a."

Family S., 5310 St. Lorenz, Austria

Year of construction 2009
Heated area 158 m²
House type Low-energy house
Number of persons 4
Heat pump NEURA NDX® Pro D8 EuP
Customer comment

"We are very satisfied with the heat pump for heating and also for hot water.
The predicted power consumption is exactly € 500. – for heater and hot water - brilliant!!"

Family H., 2433 Margarethen, Austria

Year of construction 2008
Heated area 183m² (+94m² basement - 60m² of that equipped with floor heating system)
House type Low-energy house
Number of persons 4
Heat pump NEURA NDX® Pro D7/14Wi
Customer comment

"We are very satisfied with the geo-thermal heat pump. Cost/benefit and quality have convinced us.
Low installation effort and no maintenance costs have been important factors.
We already have recommended the heat pump, which is already in use, too."

Family P., 4694 Ohlsdorf, Austria

Year of construction 2008/2009
Heated area 160m²
House type Bungalow
Number of persons 4
Heat pump NEURA NDX® Pro D5/10Wi und B300W
Customer comment

"We have found the best system to heat up our house with the NEURA heat pump and a very good system for hot water with the air heat pump. Even in the first winter we were able to spend comfortable months thanks to the floor heating system - without any problems.

 

We have also been enthusiastic about the system in the last couple of years and the heating costs have dropped tremendously compared to before. Furthermore a heat pump has been selected for us able to heat up the attic as well, which still is under construction. The necessary pipes in the attic have already been installed upon construction of the house."


 

Family P., 9220 Augsburg near Velden, Austria

Year of construction 2011
Heated area 183 m²
House type New build
Number of persons 4
Heat pump NEURA NDX® Pro D 10 EuP
Customer comment

"We have a NEURA heat pump with surface collectors in the ground for the floor heating system (the ground floor, first floor and office space in the basement are heated) and an additional NEURA air heat pump in the basement for heating up service water. The NEURA company employees have been very kind and able and as a result the installation has been quick and uncomplicated.

 

We have moved in in September 2011. The entire plant is already running for more than one year. We are very happy about very low heating costs, maintenance-free operation, independence of fossil fuels and a pleasant indoor temperature throughout the year. We gladly recommend NEURA based on our experiences."

 



Family M., 4492 Hofkirchen, Austria

Year of construction 2009
Heated area 146m²
House type Single-family house in wooden frame construction / low-energy house
Number of persons 4
Heat pump NDX ProD8EuS analog
Customer comment

"After initial scepticism how this would work with the floor heating system, we were convinced to do the installation after a very good technical education and now we are happy about having the heat pump, whenever we have to pay heating costs.
 
The major advantages for us are:
 
• Cost/benefit
• Space-saving design
• The system is nearly maintenance-free
• And the most important fact: the heating costs per year are very low"

Family H., 9100 Völkermarkt, Austria

Year of construction 2011
Heated area 130 m2
House type Flat roof
Number of persons 4
Heat pump NDX® Pro D10 EuS
Customer comment

"Excellent guidance (Mr Kienzl), good cost-benefit ratio, very recommendable. I especially liked the service delivery – even 1 year after the installation. Thank you!!
 
Kind regards,
 
a very satisfied customer"

Family H., 8042 Graz, Austria

Year of construction 1938
Heated area 110 m²
House type Solid brick building, no insulation, no underground level
Number of persons 2
Heat pump NDX Pro D5/10Wi
Customer comment

"The requirements for installation a heat pump in our house have not been very promising. Nevertheless I decided after intensive consulting service to shut down the oil heating and to install a heat pump. The radiators remain and the oil heating should only be used in exceptional cases for peak shaving.
 
Résumé after four heating periods:
 
Never had to heat with oil again, peak supply temperatures of 55°C have been achieved. The heat pump was running nearly permanently upon long-lasting low temperatures.
Thanks to the savings in energy costs I know I have made the right decision in switching to another technology.
 
Energy consumption per year:
Average 6500 KWh. Energy costs of approx. 1100 € --> conforms to current savings compared to oil heating of 50 %."

Family F., 4892 Pfaffing, Austria

Year of construction 2007
Heated area 120 m²
House type Prefabricated house
Number of persons 4
Heat pump NDX Pro D5/10Wi
Customer comment

"We are very satisfied with the NEURA heat pump. We heat using the NEURA heat pump with surface placement and floor heating system and the water is heated by an air heat pump.
 
The advantages for us:
• Low heating costs
• Simple handling
• Low space requirement for the technology in the house
• No heating device
• Warm floor is very pleasant"

Familie H, 9065 Ebenthal, Austria

Year of construction 2011
Heated area 165 m²
House type
Number of persons
Heat pump NEURA NDX Pro D10 EuS
Customer comment

Die kompetente Beratung und die 10-Jahre-Premium-Garantie haben uns zum Kauf einer NEURA Wärmepumpe überzeugt.

 

Wir sind sehr zufrieden mit der Wärmepumpe und angenehm überrascht über die niedrigen Heizkosten!

Ein herzliches Dankeschön an das Team der Firma NEURA!

Year of construction
Heated area
House type
Number of persons
Heat pump
Customer comment

Year of construction
Heated area
House type
Number of persons
Heat pump
Customer comment

Year of construction
Heated area
House type
Number of persons
Heat pump
Customer comment

Year of construction
Heated area
House type
Number of persons
Heat pump
Customer comment
Non-binding consultation